Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics. / Andersen, Michael Aagaard; Schouenborg, Jens.

In: Scientific Reports, Vol. 13, No. 1, 16090, 2023.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Andersen, MA & Schouenborg, J 2023, 'Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics', Scientific Reports, vol. 13, no. 1, 16090. https://doi.org/10.1038/s41598-023-43297-2

APA

Andersen, M. A., & Schouenborg, J. (2023). Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics. Scientific Reports, 13(1), [16090]. https://doi.org/10.1038/s41598-023-43297-2

Vancouver

Andersen MA, Schouenborg J. Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics. Scientific Reports. 2023;13(1). 16090. https://doi.org/10.1038/s41598-023-43297-2

Author

Andersen, Michael Aagaard ; Schouenborg, Jens. / Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics. In: Scientific Reports. 2023 ; Vol. 13, No. 1.

Bibtex

@article{97d1e53ebf8540b1b7fb14e2602a7700,
title = "Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics",
abstract = "Optogenetics is highly useful to stimulate or inhibit defined neuronal populations and is often used together with electrophysiological recordings. Due to poor penetration of light in tissue, there is a need for biocompatible wave guides. Glass wave guides are relatively stiff and known to cause glia reaction that likely influence the activity in the remaining neurons. We developed highly flexible micro wave guides for optogenetics that can be used in combination with long-lasting electrophysiological recordings. We designed and evaluated polydimethylsiloxane (PDMS) mono-fibers, which use the tissue as cladding, with a diameter of 71 ± 10 µm and 126 ± 5 µm. We showed that micro PDMS fibers transmitted 9–33 mW/mm2 light energy enough to activate channelrhodopsin. This was confirmed in acute extracellular recordings in vivo in which optogenetic stimulation through the PDMS fibers generated action potentials in rat hippocampus with a short onset latency. PDMS fibers had significantly less microglia and astrocytic activation in the zone nearest to the implant as compared to glass. There was no obvious difference in number of adjacent neurons between size matched wave guides. Micro PDMS wave guide demonstrates in vivo functionality and improved biocompatibility as compared to glass. This enables the delivery of light with less tissue damage.",
author = "Andersen, {Michael Aagaard} and Jens Schouenborg",
note = "Publisher Copyright: {\textcopyright} 2023, Springer Nature Limited.",
year = "2023",
doi = "10.1038/s41598-023-43297-2",
language = "English",
volume = "13",
journal = "Scientific Reports",
issn = "2045-2322",
publisher = "nature publishing group",
number = "1",

}

RIS

TY - JOUR

T1 - Polydimethylsiloxane as a more biocompatible alternative to glass in optogenetics

AU - Andersen, Michael Aagaard

AU - Schouenborg, Jens

N1 - Publisher Copyright: © 2023, Springer Nature Limited.

PY - 2023

Y1 - 2023

N2 - Optogenetics is highly useful to stimulate or inhibit defined neuronal populations and is often used together with electrophysiological recordings. Due to poor penetration of light in tissue, there is a need for biocompatible wave guides. Glass wave guides are relatively stiff and known to cause glia reaction that likely influence the activity in the remaining neurons. We developed highly flexible micro wave guides for optogenetics that can be used in combination with long-lasting electrophysiological recordings. We designed and evaluated polydimethylsiloxane (PDMS) mono-fibers, which use the tissue as cladding, with a diameter of 71 ± 10 µm and 126 ± 5 µm. We showed that micro PDMS fibers transmitted 9–33 mW/mm2 light energy enough to activate channelrhodopsin. This was confirmed in acute extracellular recordings in vivo in which optogenetic stimulation through the PDMS fibers generated action potentials in rat hippocampus with a short onset latency. PDMS fibers had significantly less microglia and astrocytic activation in the zone nearest to the implant as compared to glass. There was no obvious difference in number of adjacent neurons between size matched wave guides. Micro PDMS wave guide demonstrates in vivo functionality and improved biocompatibility as compared to glass. This enables the delivery of light with less tissue damage.

AB - Optogenetics is highly useful to stimulate or inhibit defined neuronal populations and is often used together with electrophysiological recordings. Due to poor penetration of light in tissue, there is a need for biocompatible wave guides. Glass wave guides are relatively stiff and known to cause glia reaction that likely influence the activity in the remaining neurons. We developed highly flexible micro wave guides for optogenetics that can be used in combination with long-lasting electrophysiological recordings. We designed and evaluated polydimethylsiloxane (PDMS) mono-fibers, which use the tissue as cladding, with a diameter of 71 ± 10 µm and 126 ± 5 µm. We showed that micro PDMS fibers transmitted 9–33 mW/mm2 light energy enough to activate channelrhodopsin. This was confirmed in acute extracellular recordings in vivo in which optogenetic stimulation through the PDMS fibers generated action potentials in rat hippocampus with a short onset latency. PDMS fibers had significantly less microglia and astrocytic activation in the zone nearest to the implant as compared to glass. There was no obvious difference in number of adjacent neurons between size matched wave guides. Micro PDMS wave guide demonstrates in vivo functionality and improved biocompatibility as compared to glass. This enables the delivery of light with less tissue damage.

U2 - 10.1038/s41598-023-43297-2

DO - 10.1038/s41598-023-43297-2

M3 - Journal article

C2 - 37752160

AN - SCOPUS:85172338310

VL - 13

JO - Scientific Reports

JF - Scientific Reports

SN - 2045-2322

IS - 1

M1 - 16090

ER -

ID: 369079264