Magnetic field associated with neural activities in an isolated cerebellum

Research output: Contribution to journalJournal articleResearchpeer-review

A superconducting sensor was used to measure the magnetic field evoked from the isolated cerebellum of the turtle by brief electrical stimulations of the dorsal surface. The field was generated by neuronal activities, since its amplitude was reduced when Mn2+ was applied and completely abolished with tetrodotoxin. In normal bathing medium, the field amplitude at a distance of 17 mm was as much as 1 pT, demonstrating that the magnetic technique can be used to remotely monitor neural activities in regions of 10 mm3 or even less.

Original languageEnglish
JournalBrain Research
Volume412
Issue number1
Pages (from-to)151-155
Number of pages5
ISSN0006-8993
DOIs
Publication statusPublished - 26 May 1987

    Research areas

  • Biomagnetism, Cerebellum, Magnetic evoked field, Magnetoencephalography, Neuromagnetism, Purkinje cell, Turtle

ID: 201457229